Journal Search Engine
Search Advanced Search Adode Reader(link)
Download PDF Export Citaion korean bibliography PMC previewer
ISSN : 1226-0088(Print)
ISSN : 2288-7253(Online)
Membrane Journal Vol.23 No.2 pp.185-188
DOI :

연속식 공기세정 관형막 투과특성

박 미 자, 정 건 용
서울과학기술대학교 화공생명공학과

Permeation Characteristics of the Tubular Membrane with Continuous Air Cleaning System

Kun Yong Chung, Mi Ja Park
Department of Chemical and Biomolecular Engineering, Seoul National University of Science & Technology, Seoul 139-743, Korea
(Received March 26, 2013, Revised April 10, 2013, Accepted April 22, 2013)

Abstract

This study was carried out for microfiltration tubular membrane module equipped with self-designed air injection nozzle in order to determine the permeate flux due to the effect of membrane fouling reduction. The 0.1 wt% yeast particle solution was used as a feed solution and permeation tests were performed for the cases with and without air injection. Permeation fluxes were measured and analyzed to examine the effect of membrane fouling reduction. While the permeation flux without air injection decreased continuously, that with air injection was improved more than 30 percent than that of no air injection case.

Reference